Chilled Beams

ceiling induction diffuser

Ceiling induction diffuser

Water cooling for an optimum room climate

It was developed for removing high thermal loads from air-conditioned rooms. It combines the supply of necessary, processed fresh air (primary air) with the advantages of energetic load removal by the medium water.

The low overall height of the ceiling induction diffuser is especially suitable for low heights of intermediate ceilings in new buildings and for installing it in rehabilitated buildings.

In the primary distribution channel, nozzles are collocated. The number of active nozzles can be varied and thus, the volume of the primary supply air can be adjusted optimally.

By reducing the proportion of primary air to a necessary minimum, the energy costs are reduced. The primary supply air is mixed with cooled secondary air and supplied to the room without any draught via one or two air diffusers optimisedfrom the ventilation point of view.

The ceiling induction diffuser is used as 2-conductor system for cooling.

Overview of the advantages:

  • Removal of high thermal loads possible.
  • The height of the air channel system is reduced to a minimum due to the low supply of primary air.
  • Reduction of the operating costs due to low primary air volume.
  • Improvement of the thermal environment in the room.
  • Individual adjustment of the primary air volume by means of the nozzle configuration.
  • Suitable for all standard ceiling grids.
ceiling induction diffuser DISA-HT.jpg

Ceiling Induction Diffuser

Cooling and heating

It is composed of a 4-conductor system for the connection of cold and hot water. The separation of the supply and return circuit saves energy. An example: If the room temperature is low in the morning, the air can be heated via the heat exchange system. If the temperature increases in the afternoon, it is cooled down using the cooling register. In both cases, the water needs not to be cooled or heated in all tubes - consequently, less energy is required.

The air is supplied without any draught to the room via one or two air diffusers optimisedfrom the ventilation point of view.

It is also especially suitable for low heights of intermediate ceilings in new buildings or for installing it in rehabilitated buildings due to its low overall height. In the primary distribution channel, nozzles are collocated.

The number of active nozzles can be varied and thus, the volume of the primary supply air can be adjusted optimally. By reducing the proportion of primary air to a necessary minimum, the energy costs are reduced. The ceiling induction diffuser is used as 4-conductor system for cooling and heating.

Overview of the advantages:

  • Separate cool and hot water circuit (4-conductor system).
  • Removal of high thermal loads possible.
  • The height of the air channel system is reduced to a minimum due to the low supply of primary air.
  • Reduction of the operating costs due to low primary air volume.
  • Improvement of the thermal environment in the room.
  • Individual adjustment of the primary air volume by means of the nozzle configuration
  • Suitable for all standard ceiling grids